Eplan electric p8 user manual pdf free.EPLAN Electric P8Eplan electric p8 user manual pdf free. EPLAN Electric P8 Reference Handbook
If a connection list was output as a report while working with project groups and the name of the project selected in the Connection list Total dialog in the Page navigator field, EPLAN was terminated unexpectedly. When creating a user-defined property configuration for project properties it was possible that EPLAN was terminated unexpectedly. If parts data was exported as an XML file and later imported again into a parts database, it was possible that after the import variants without function templates had the same function templates as the first variants of the parts.
If an SQL server database was set for the parts management, the filter did not work. If the dialog for printing was called up for a project without pages, EPLAN was terminated unexpectedly. This now works again. During the search for values with blanks in the parts management problems occurred if there was more than one blank in the value. Selecting a page in the tree of the page navigator by entering the first number of the page name now also functions again when the number block of the keyboard is used.
If identifiers were moved by one position by means of the arrow buttons Move up and Move down in the tree of the structure identifier management, the marker of the selected structure identifier was lost in the tree. If a QR code with a specific block property that contains format elements for the page was inserted in a form, the QR code on the generated report pages was calculated incorrectly in the project.
If the Manufacturer property was used for the tree configuration in the parts management and if it was not the last node in the tree view, not all parts were displayed. In Version Update2 the display of the path division in the graphical editor did not work when the command Schematic paths was used. If the [ For terminals to which an assembly is assigned as a part, no terminal designation has been output in the "Summarized parts list" report when a terminal strip definition was simultaneously available for the respective terminal.
The value of a user-defined property which is defined as a part reference property is now output again in the parts list for terminals to which a broken-up assembly is assigned as a part. There was a problem during the updating of stored device data when using the part selection via API.
If the Procurement property was selected as a further column in the parts management during configuration of the list, no parts were displayed in the list afterwards anymore. In the future, this will no longer be the case. The date will only be changed if any data changes due to the update of the project. In the tree of the page navigator you can now select a page again by entering the first number or the first character of the page name. This also applies for the selection of other objects layout spaces, devices, etc.
The performance when working with the new parts management has been improved for example with large data amounts, for the filtering by part numbers, etc. If a part number was entered manually in the Edit terminal strip dialog or when editing in tables for a terminal it was possible that the part variant had an undefined value.
Now the part variant is set again to the default value "1" in this case. If a user-defined tree configuration with multilingual property was used for the part selection, a part which was already assigned to a function was not pre-selected in the tree during the part selection.
If an accessory list was selected in the Accessories tab of the parts management, only accessory lists could be selected for a further accessory selection, but not parts.
In the process display problems occurred in some languages. To use existing user-specific ribbons you can, for example, convert these in the default text editor Notepad into the format "UTF LE". Only a limited number of values could be copied from Microsoft Excel and pasted for editing in a table. For assigned structure segments which already existed in the pre-planning, the connection to the placeholder object is removed.
In the dialog Format for block properties, the two fields Navigation and Preview are now adapted to the size of the dialog. This means that with longer texts you do not have to work with scroll bars anymore to fully read this information.
If table cells were copied in the property tables, it was possible that the column headers were copied as well even though they were not marked.
Now the column headers are only copied into the clipboard if they are also marked. As part of this change the contents of the clipboard are now saved in HTML format when copying table cells. This way the column header is also inserted by default when a copied table cell is inserted in Excel.
If you want to insert only the text of the table cell, you have to insert the contents of the clipboard as text without formatting by using the "Paste Special" command in Excel. In the Insert center tags with a dot in the name were not saved correctly. The dialog Rename which allows you to assign an image file when customizing the ribbon has been expanded for this purpose with the buttons and.
The button is used to open a selection dialog where you can select and import the desired image file. Only svg graphics can be used. When customizing the ribbon, a Tooltip and a description can now be specified for actions.
To this purpose the Rename dialog for actions should be extended with the corresponding fields. In Version Update1 the designations of these fields are only displayed in English. Extension of the class "RibbonCommandGroup" for the assignment of user-defined images.
If multiple layout spaces were copied in a project and inserted into another project using the Clipboard and existing layout spaces were overwritten in the process, it was possible that items such as, for example, a mounting panel were not displayed in a copied layout space even though they were available in the layout space navigator. It is now possible to query and specify the field type for user-defined properties in parts management by means of the new property " FieldType " from the class " MDUserDefinedPropertyDefinition ".
Because such commands are assigned to different command groups depending on the context opened editor , problems arose when such a command was added to the toolbar. This has been solved. In the past all macros were checked. To accelerate the macro collection update, the update now only takes place for the new macro. The remaining macros of the macro collection are not checked. In scripts you can now also access the parts management and, for example, edit the properties of parts.
In the name space Eplan. MasterData the required classes are available. When a device is placed on a mounting panel in the 2D panel layout the dimensions stored at the part are now considered again for the setting Macro and dimensions from parts master data when the macro of the part does not contain the correct representation type. This now works.
During the part selection a part can now be transferred again to the property dialog with a double-click. Exit was executed, without the [Enter] key or the [Spacebar] being selected. If block editing was performed for several main functions or connections and a part number was entered manually there, a memory access violation occurred under specific conditions. This lead to the selected part only being entered at the first main function or connection.
During the change of standard symbols which were partially outside the plot frame were not taken into consideration. The graphic at the cursor is now visible again immediately when symbols are inserted by means of shortcut keys e. When using an SQL server for the parts database it happened under specific conditions when the parts management was opened that the SQL database was set to the single-user mode and remained in this mode.
The performance when assigning parts data has been improved for the Synchronize devices dialog which is opened during the import of device data. If this procedure takes some time, a progress bar is now displayed. During the DXF export of terminal diagrams an incorrect display of jumpers occurred on the output pages. When placing accessory parts, an incorrect placement occurred under certain conditions.
When repeatedly importing property arrangements in the Configure property arrangements dialog, property arrangements were created multiple times under certain conditions. When inserting accessories, 3D macros with only a variant B were ignored. The new Insert center allows you to insert different objects such as symbols, devices as well as window and symbol macros directly via a shared dialog onto project pages or into layout spaces.
In addition the dialog provides various quick access possibilities which allow you to accelerate the design stage. You can now choose between light and dark design for the user interface. Commands for the navigators and graphical editors are now no longer selected via menu and toolbars, but by means of a ribbon.
This ribbon is similar in functionality and structure to the ribbons known from Microsoft Office products. As part of the redesign of the user interface with new elements such as the Ribbon and the Quick access toolbar there is also a new dialog Customize to make user-specific customizations at these elements. The specification of shortcut keys is now no longer carried out by means of a settings dialog but while customizing the ribbon or the quick access toolbar.
To this purpose you can branch to the new subsequent dialog Customize shortcut keys by using the button [Customize] in the Customize ribbon tab of the Customize dialog. The previous settings dialog has been removed. The selection of a workspace now takes place via a button in the ribbon.
By clicking the button you open a drop-down list in which you can select the desired workspace. You can have a menu bar with the "old" menus from Version 2. Previously the pages, layout spaces, etc. Now you have the possibility to also define undocked editors as main working windows. The popup menu item Main working window is available to this purpose in the title bar of the respective editor.
An editor activated as a main window is highlighted by a blue frame. The solutions of the EPLAN Platform offer the Backstage view as a new feature - the functionality to comfortably edit, back up, organize, print and pass on your projects.
You are already familiar with such a Backstage view from Microsoft Office products. As part of the redesign of the user interface different functionalities that refer to the work with projects were moved to the Backstage view.
In the course of the redesign of the user interface many dialogs in which you select a file or a directory for example Open project , Open form , Select folder have been adapted to a modern Windows "look and feel". Opening these dialogs now instead takes place by using the button [ As part of this redesign of the user interface the appearance and behavior of the tables has partially changed.
To optimize the display the new popup menu item Column width automatic is available in many dialogs, and in some dialogs with property tables e. In the course of the new user interface the behavior of the icons in the status bar has also changed.
For example, one click on the icon is now enough to open the system message dialog. Several terms which are used in the project structures and structure identifiers have been renamed. The identifier block "Higher-level function" is now called "Function designation" and the identifier block "Mounting location" is called "Location designation". After opening with these shortcut keys the cursor is located in the search field of the Insert center and you can start immediately with the search.
In the course of the redesign of the user interface, the symbol navigator has been removed and is now also no longer available as a command. In addition the part master data navigator is only available as a command in the Customize dialog. After marking one or more rows in the new version the selection made is indicated through a blue frame.
To be able to insert the selected functions on a page, you have to position the cursor on this frame. Only then can you drag the selection made into the graphical editor.
In the Property overview dialog you can specify the display of the properties by means of the buttons All properties , Filled properties or From scheme. If one of these buttons is activated, you can switch between a tree view and a list view by means of the buttons Tree view and List view.
This corresponds to the behavior for the display in the properties in the new Properties tab in the parts management. Basic projects offer the advantage that they amongst others also contain master data for example forms and symbols or referenced data for example image files stored in the project.
Project templates can no longer be selected or created. Accordingly the Create project template dialog has been removed. In addition, the Template field has been renamed to Basic project in the Create project dialog. As part of miscellaneous extensions and optimizations, the project databases have been changed in Version This has the effect that new projects are essentially created with new project databases.
In the course of the redesign of the user interface, the menu item Publish has been removed and is now also no longer available as a command. The associated dialogs have also been removed dialogs Publish and Settings: Publish. The menu items for redlining of projects via PDF comments have been removed Comments navigator , PDF comments and are now also no longer available as commands.
You can now also determine the source and target of connections manually. This property is available to you in the property dialog of functions in the subsequent dialog Connection point logic. In the settings for the connection numbering you have the possibility to specify a reset range for the counter. Depending on the criteria specified there, the counter starts again with the start value if the page or a structure identifier, for example, has changed.
Now you additionally have the possibility to have the counter reset when the schematic path changes. The previous database technology for the parts management was outdated and has been revised for the current version. To exchange data it is now possible to use external editing in the parts management. To this purpose the new menu item Edit properties externally with the two submenu items Export data and Import data is available in the parts management below the [Extras] button.
However, it is possible to transfer "old" parts databases into new databases in the parts management. To this purpose you can select old databases in the Settings: Parts user dialog during the selection of the database source. In the course of the restructuring of the parts management, the user-specific setting Use SQL Server full-text search that is no longer needed has been removed from the Settings: Parts dialog. Therefore it is no longer possible to open the Festo product catalog in the new parts management.
The popup menu item Festo shopping basket has also been removed in the Device list dialog. The two functionalities Calculate prices and Convert currencies have been removed in the course of the redesign of the parts management. Therefore the two menu items Prices and Currencies are not available below the [Extras] button. The two menu items Space requirement and Update search index are also removed in the course of redesign. No tab, but rather a dialog, is now available in the parts management for the maintenance and management of free properties.
This dialog is accessed from the tab User-defined properties by using the button [Free properties]. By means of a configuration of the tree view you can specify in the parts management which additional information is to be shown to you for quicker identification of parts. In the new version such a configuration is not only possible for parts but for other objects accessory list, drilling pattern, etc.
In addition further information can now also be shown for the part variants. To this purpose the Configure representation dialog has been extended with the configuration possibility for objects such as "part accessory list", "part drilling pattern", etc. The new check run in the message class "Part master data" is available to find the relevant part. In addition it is thus also possible that different ERP numbers are available for the variants of a part. The new check run is available to find the differences between the variants of a part.
The Generate part command allows you to create a part from the schematic data. The subdevices are now also considered and the device data of the subdevices is transferred into the part. The Macro property which was previously placed on the Technical data tab has been renamed to Schematic macro. This means that this property can be more easily differentiated from the property Graphical macro where, for example, 3D macros for the layout space are placed. Both properties are now located on the Properties tab.
The Schematic macro property in the Data hierarchy level and the Graphical macro property in the Mounting data hierarchy level. Enter the number here which was assigned by the UL organization during the certification of the part.
Both identifiers can be found in the UL database. For parts from the "Mechanics" generic product group you also have the Function templates tab available instead of the Function definition tab. For a mechanical part you can only specify one function template here. Accordingly, only one line with the columns Function definition and Item is available for such a part.
This line can neither be deleted nor can other lines with function templates be added. The classification of a part into "Generic product group", "Product group" and "Product subgroup" is now carried out with the new property Product grouping ID In this property from the "General" hierarchy level the classification is shown like a directory path in a breadcrumb trail e.
To change the classification, click the Properties tab for the property Product grouping in the column Value and on [ From the drop-down list with the product groups double-click to select the desired product subgroup e.
After application of the modifications the new product grouping is also displayed for the hierarchy levels in the tree. The menu item Sum up function templates below the [Extras] button has been renamed to Summarize function templates. In the parts management it is now possible to filter the parts according to function definitions and other data of the function templates e.
For this reason the criteria selection of the filter has been expanded with the following entries:. At a project-specific part selection, only those parts are offered which are stored in the project. If such a part selection was set in the Settings: Part selection dialog in the "Project" option, an mdb database was previously created as a file for the parts stored in the project.
This file is not required anymore. When using a project-specific part selection you now work directly in an internal project parts database with the parts stored in the project.
The quality of the representation of objects on pages has been improved decisively by a change to a new technology in the graphical output in the 2D section: The speed while drawing, marking and selecting components, graphical elements and texts has increased significantly.
Thanks to the improved graphical representation the texts are now easier to read. Zooming and moving of schematic objects has also been significantly increased. In the context of this new feature, property texts of a component are now highlighted with a temporary frame when a component is marked in a graphical editor.
The scroll bars in the graphical editor and the associated user-specific setting Display scroll bars have been removed. An enlarged or reduced window pane of an editor can still be conveniently moved with the mouse mouse wheel or middle mouse button. The possibility to specify manual sorting of the pages for list views has been removed. The popup menu item Manual page sorting in the page navigator, the subsequent dialog by the same name as well as the associated project-specific setting in the Settings: Pages dialog are now not available anymore.
Printing project pages now takes place via the Print Backstage view. As part of these modifications the Print dialog has been revised. The print preview has been integrated into the Print dialog and is not called up anymore as a separate dialog. In addition only those pages are now displayed in the print preview which are also printed. Printing of attached documents now takes place via the Print Backstage view. Accordingly the menu item Print attached documents has been removed and is now also not available as a command anymore.
The Print attached documents dialog has been redesigned and renamed into Select attached documents. The number of the placeholders that can be used in the keywords of the dictionary has been increased from previously 10 to now. Since Version 2. The Multilingual input dialog is now opened by double clicking the icon. If an object on a page is deleted in a revision project, the page is now identified as "Draft", irrespective of the project setting While deleting create deletion markers and list deleted pages.
This page can thus be completed and provided with a revision index. The user-defined properties for this part are now also available to you in the parts management for the configuration of the tree view and list view.
In addition these user-defined properties can now also be used as filter criteria for the parts pre-filtering. Furthermore these user-defined properties can now also be selected in the bill of materials and in the 3D mounting layout navigator as filter criteria in the Criteria selection dialog below the hierarchy level "Part".
If you import parts from Version 2. A corresponding message is displayed in the system messages in this case. User-defined properties without definition cannot be edited in the User-defined properties tab of the parts management.
You can use the popup menu item Configure properties here to open the configuration dialog. The Configure properties dialog has sensible values directly pre-assigned. After you have applied the changed configuration and closed the dialog again, you can edit the user-defined property in the User-defined properties tab.
The new check run in the message class "Part master data" is available to find parts in the parts management that have user-defined properties without an assigned definition. If a PLC connection point, bus port or device connection point was reported as faulty during the check, the combination of plug designation and connection point designation of this connection point is displayed here. The functionalities for sending projects as e-mails have been removed from the user interface.
Accordingly the menu item Send by e-mail has been removed for example in the project management , and is now also not available as a command anymore. The notification of further users via the popup menu item Send e-mail message in the dialogs Show user and Multi-user conflict is still possible. This now takes place via the e-mail program which is installed on the computer and is entered as default e-mail app in the Windows settings. The packing of projects in order to reduce storage space is generally not required anymore.
The Pack menu item in the project management has been removed accordingly and is now also not available anymore as a command in the EPLAN Platform. Packed projects for example from previous EPLAN versions are now automatically unpacked while opening a project in the Backstage view. To back up and restore Master data one dialog is now available instead of numerous menu items and dialogs.
The master data to be backed up and restored, such as, for example, "Parts data", "Basic projects", "Forms", etc. The other fields and settings are otherwise familiar to you from the previous dialogs for backing up and restoring from previous versions.
Accordingly, the Settings: Projects dialog in the user settings has been removed. You can now store informative descriptions for the selected actions in a scheme for the automated processing. This is of interest if you want to perform multiple similar actions for a scheme for example multiple actions for the output of labeling data for different output types.
To this purpose a new Description column is now available for the table with the selected actions in the Settings: Automated processing dialog. The text entered here is additionally displayed in the Run: Automated processing dialog. Previously it was not possible to specify the name of the backup file for the action "Back up data" in automated processing.
The project name was always used as the backup file name. To be able to specify the name, the field Backup file name including a subsequent dialog for file selection has been added to the dialog Back up data. In the course of the introduction of the Backstage view the functionality Correct project has been renamed to Clean up project.
In the associated settings dialog Settings: Clean up , which has also been renamed, the hierarchy level Cable with the two settings located below it, Move contents of Remark field from cables and shields to function text and Remove blank characters from cross-section information at cables, shields, and connections has been removed.
These options for the correction of cables was only used for older projects that were imported from EPLAN 5. In combination with the introduction of the Backstage view the functionalities for compressing and reorganizing projects were combined. The menu item Reorganize has been removed accordingly in the project management. The reorganization now takes place during the project compressing. To this purpose the dialog Settings: Compression below the hierarchy level Reorganize project has been extended with the setting Advanced mode for the correction of the project database.
Furthermore the filter in the Compress project dialog has been removed. In the case of the compressing of projects the two hierarchy levels Symbols and Comments with the settings located below have been removed from the dialog Settings: Compression check boxes Remove unused alternative symbol variants , Remove unused symbol variants and symbols and Remove comments. In accordance with the redesign of the user interface, the layout of the help system has additionally been customized for this version.
The help has been designed more reader friendly by using a larger font size and uniform formatting of elements such as notes and tips. The navigation area with the tabs "Contents", "Index" and "Glossary" has been changed to a side navigation bar. You can expand and collapse the subordinate help topics by using the arrow buttons displayed next to the entries.
As part of this modification the search via the index and the separate display of the glossary have been removed. Macros are now inserted by means of the new Insert center.
In the course of this extension the Graphical macro selection as well as the associated settings have been removed from the user interface.
Numerous feedbacks have shown the demand to change the settings for the default 2D panel layout setting Macro and dimensions from parts master data in the available default setting. Therefore the Macro from parts master data option is now set as a default for the application in the Settings: 2D panel layout dialog. With this option the macro entered in the part is placed using its original dimensions. Source and target of a cable are determined according to specific rules in EPLAN from the DTs of the functions that are connected to the individual cable connections.
Alternatively to this, source and target of a cable can now also be determined through the source and target of the cable connections. The new project setting Determine source and target of the cables via the cable connections is provided to this purpose. The address is broken down into different levels. In the past the individual levels were identified by means of separators. Different variants exist in the AutomationML format depending on the respective usage.
The start addresses of the PLC box can now be automatically generated by means of the data length entered there. The new Generate start addresses of the PLC cards dialog is available to this purpose.
When filtering the assignment list, many other properties are now possible as filter criteria, such as Data type , Channel designation , Direction , Symbolic address etc. This way the assignment list can for example be filtered for inputs via the Direction property. In the course of this change, the report "PLC address overview" has been extended with additional placeholder texts and filter possibilities, for example for the function text and the channel designation. During the import of PLC configuration files the format of the import file is now automatically detected for many common PLC configuration programs and does not have to be selected manually anymore.
A file selection dialog is now displayed before the Import PLC data dialog. Depending on the PLC configuration file selected, the matching format is then preset in the Format of import file field. Display of the function text in the rack-oriented view of the PLC navigator. In the rack-oriented view of the PLC navigator you can now additionally display the function text of the PLC box at the rack.
To this purpose the new "Function text: PLC box rack-oriented view " object is now available in the Configure representation dialog. For this object click [ In the Format dialog, double-click in the list of available format elements on the entry "General function" and select the "Function text automatic " entry in the subsequent dialog Format: Block property.
Detailed information on this is available from the PLC manufacturer. At bus ports the new property Standard gateway ID is now available. Here you can enter the standard gateway for example, a router to which bundles that cannot be directly delivered within a LAN are sent. To differentiate, the old properties for the standard gateway, that are only available for reasons of compatibility to older EPLAN versions, are identified with the supplement "Do not use anymore".
As of Version some outdated interfaces to the PLC configuration program are not supported anymore since the manufacturers are changing over to the new AutomationML standard. Network structures and bus interfaces are defined via the bus ports. The entry of bus data at the PLC box is not required.
According to standard IEC these characters are not permitted in a symbolic address. The alignable accessories of terminals and terminal strips are now always visible in the dialog Edit terminal strip and cannot be hidden. Accordingly the popup menu item Alignable accessories visible has been removed. During the copper DXF export of manufacturing data for the machining it is now also possible to transfer DXF data for busbars made of copper to the Steinhauer ModCenter. There is now an interface for the export of manufacturing data to the manufacturing planning and control program Rittal - RiPanel Processing Center.
After selecting the command the export dialog is opened where you can specify the name and the directory for the target file. A new interface is available for the bidirectional data exchange of Rittal parts data with the configurator software Rittal Configuration System. To this purpose the following commands are available in the Backstage view for exporting and importing data:. When determining the format for block properties the new format element "3D part placement" is now available in the Format dialog for functions below the "Function" entry.
By means of this format element you can access properties of the 3D part placement during the definition of block properties for example Layout space description , Item designation , etc.
Placement of busbar supports on user-defined rails has been made easier. The busbar supports now also snap onto the guide rail of a user-defined rail. When inserting locked areas restricted placing areas, restricted cut-out areas the Placement options dialog is no longer available.
Before placing parts for example by inserting as a device from the Insert center you can manually enter the part dimensions of the parts for example via the Insertion as a device function from the Insert center to be placed in the Dimensions dialog. Writing back of the entered values in this dialog into the new parts management is not possible anymore. For this reason the Write back dimensions to part check box has been removed.
When rotating the viewing angle or when moving the selected items in a layout space associated multi colored part placements are now displayed during the action with one single color for a short time.
This way the performance could be improved during the rotation of the viewing angle and while moving. The functionality Restricted drilling area has been renamed to Restricted cut-out area since these locked areas prevent any type of cut-out.
If PLC devices were placed on bases with the same DT, problems with the routing occurred because connection points existed double in the connection point patterns. A connection point pattern was generated from the function templates at the part of the PLC device, a connection point pattern was stored at the part of the respective base.
If multiple items are now placed that have the same DT, a check is carried out whether one of these devices has a connection point pattern. If this is the case, no connection point pattern is generated from the function templates of the other parts anymore. Therefore routing in the layout space is now also possible for such PLC devices.
Excluding model views for the output of labeling data for enclosure legends. The Suppress generation of the enclosure legend property in the model views now also has an effect on the output of the labeling. If the check box is activated, the respective model view is not taken into consideration during the output of the labeling for the report type "Enclosure legend".
With automated processing the manufacturing data for machining at NC machines can now be automatically exported as DXF files. Both export interfaces for Rittal - Perforex do not only output data for machining of housings and flat parts to the respective Perforex system but also data for cutting wire ducts, mounting rails and C horizontal rails to the Rittal Secarex AC 18 cutting center.
You now have the possibility to specify the export scope in both exports. A new setting is now available in order to influence the page names of the generated pages when placing page macros from the pre-planning navigator. The new Remove method from the Location class allows you to remove an unused structure identifier from a project.
With the IsUsed property you can check beforehand whether the structure identifier is used. Through a new overload of the Mirror method from the Edit class not only graphical elements, but rather all objects, for example symbols, can be flipped around a freely selected flipping axis in the graphical editor.
In this context you can optionally select whether a copy of the original objects is created during flipping. MasterData you can now determine the connection category for the connection points of a connection point pattern in the parts management via EPLAN API and change it, if necessary. The new CreateDatabase method is now available in the ProjectManagement class. This method can be used to create a new Access or SQL Server database for the project management and use it directly. The subprojects action has been extended.
During "Generate project reports" with the GenerateProject method from the Reports class, model views etc. The Macro class contains the new property CustomLayerTable by means of which you can list which user-defined layers a macro contains. Further information You can now also determine the currently selected layout space by means of the selectionset action. You can now determine which functions of a specific function-related report are output by using the new property Functions from the class ReportBlock.
You can now determine which connection point pattern is stored at a part by means of the new property ConnectionPointInfo from the MDPart class. You can now determine the rotation angle or the coordinates of an offset at 3D objects in a layout space by means of the new RelativeTransformationOfMacro property from the Placement3D class. The original methods were marked as out-of-date. The actions backup and projectmanagement have been adapted correspondingly. The variables Backup. Medium and ProjectManagement.
Medium were also identified as out of date. In the current version the menu item Publish as well as the associated dialogs for publishing projects have been removed from the EPLAN Platform. In the course of this redesign the PublishProject method from the PartsService class has been marked as obsolete and should no longer be used. The translate action has been extended.
The new Place method is now available in the Function class. This method allows you to place functions from the project data navigators in the schematic. In the process PLC channels are correctly used, for example. In the user interface, this corresponds to the popup menu item Place. In the Decider class a new overload of the Decide method exists that allows you to transfer a selection list with multiple entries.
The selection of the commands for the navigators and graphical editors in the user interface of the EPLAN Platform now takes place by means of a ribbon. The following four new classes are available in the namespace Eplan. The MDPartsDatabase class has been extended by the new method GetParts which allows parts to be filtered for different properties. This new method allows to determine the parts found by a field-based filter scheme.
The export of parts now takes place via the MDPartsDatabase class. The previous methods for the export of parts in the PartsService class have been identified as outdated. In the course of this change methods from the class Eplan.
PartsService which apply to the parts management were moved to classes within the namespace Eplan. Masterdata and identified as outdated in the class PartsService. This section provides information about the new symbols that are available to you in the master data as of the current version. This section provides information about the most important modifications for the plot frames and forms. In the Suggested identifiers dialog an identifier set for the standard IEC which considers the modifications of Version is now also available.
A new IEC column was added correspondingly to the dialog. If only the DT component e. This is the same behavior as before Version 2. If the DT component and the additional name element are assigned to the properties in the placeholder object e. Specific values were not output in a terminal diagram when the reports for a terminal were divided by a line break.
The faulty elements are logged in the system messages. Check run has been extended. A message is output when the "Function definition" ID property differs at the different representation types of a connection. During the output of labeling data for the report type "Terminal diagram" an unexpected error message occurred during the usage of a special Excel template which prevented the further export.
After a connection test in the Settings: Internet connections dialog it was possible that the icons in the "Status" column were dynamically magnified in an undesired way.
These have been corrected. If an object was marked and edited in an undocked navigator for example the property dialog was opened , the marking subsequently no longer existed in the navigator. For the "CreateProject" method from the "ProjectManager" class, the error message that occurs when the method was called with an outdated basic project has been improved. The objects covered with a fill surface in the graphical editor were partially still visible. The function definition of the generated connection is now accepted by the multi-line connection point of the source.
During connection numbering the manual sorting sequence of the pages is now taken into consideration when it is relevant for the set format.
Multi-line texts which had the "Middle center" setting for both the alignment and the base point in the property arrangement were displayed slightly offset in the layout space. In specific cases targets of interruption points were not found, if the search extends over multiple interruption points. During the export of pages as DXF files and usage of the default scheme it was possible that specific symbols were exported several times.
During the output of the labeling for the "Cable diagram" report type no values were output during the selection of indexed part properties for the source and target part at the "Type number" format element.
After aligning and formatting connection definition points, the check run also reported connection definition points which were located on an individual connection. When assigning value sets the property arrangement specified for a symbol in the placeholder object was not applied. The symbol variant and the property arrangement can now be specified simultaneously via a placeholder object. During the report of a terminal diagram a problem occurred with the display of further layers during the display of jumpers for multi-level terminals.
When specific plot frames were opened in the plot frame editor, both the selected plot frame and the plot frame of the opened project were displayed in the graphical preview.
During the output of labeling data a language identifier instead of a number is output for the project property Source language for example en-US. During an export of the missing-word list, no comments were exported for ambiguous texts for which there are different translations. If layout display windows with an invisible frame were located in a DXF file, the contents of this display window were previously not imported.
The "Enclosure legend" report could not be updated if the view name of the underlying model view contained square brackets "[]". The project property Highest revision index ID was not offered for selection during the creation of block properties. While inserting a device or generating terminals as a device it was possible that the number of connection points of the function was changed. This problem occurred when a symbol which had fewer connection points than the associated function definition was entered in the function templates of the part and modifications were made in the connection point logic of the symbol.
The number of connection points of the function now also remains in such a case. If you automatically generate drilling patterns from a macro project and agree to the update during the transfer into the parts management, the existing drilling patterns are no longer generated again, but only updated.
If a rotation angle was set for the part placement in the settings for the 2D panel layout, the handle was located after the placement at a position that did not take the angle setting into consideration.
If a complete terminal strip was placed in the layout space from the 3D mounting layout navigator, terminal parts with a number of units "0" were also considered. Problems occurred when an assembly for which a macro with mounting rail is stored was inserted as a device in the layout space. The assignment of cable cores from the cable navigator behaved differently than the assignment of cable cores from the pre-planning navigator. Under specific conditions texts combined into a block were not represented correctly during printing.
The contents of the property IDs for net-based connections ID could not be deleted manually, and the property could also not be deleted from the property table.
When placing a macro in the layout space by means of insertion as a macro or as a device, the property arrangement specified as default for the project was not used - even though the "Default value" was specified for the property arrangement of the associated part placement.
For properties with which the form to be used can be specified Cable assignment diagram form , Cable-connection diagram form , etc. If a stored form is not used in the process, it is stored in the project when the form is assigned via the value set of the function.
Under specific conditions, model views were not correctly generated in the desired page structure. If a QR code included texts with accent marks such as Czech characters , these characters were not recognized correctly by mobile devices tablet or smartphone. During the output of labeling data and the "Summarized parts list" report the cable lengths were added up for several cables even though the Do not use cable when adding up cable lengths property was activated for these cables.
Under specific conditions, pages with model views could not be output together with the associated layout space during the PDF export. A protective cover for busbars could not be placed in the layout space if the product subgroup "Busbar cover" was set for the part.
In the case of repeated part selection of a part whose assigned user-defined properties have changed values, the user-defined properties were overwritten at the function without the conflict dialog being opened beforehand.
The "GetValue" method from the "PlaceHolder" class could previously not be used if the project was write-protected. After the placement of macros which are stored at planning objects, auxiliary functions were no longer assigned to the main function in the macro.
This, for example, results in an incorrect designation for connection definition points and device connection points. Module parts with describing structure identifiers were not filtered correctly in the 3D mounting layout navigator.
When generating a new SQL database in the Generate SQL server database dialog, the entry for the database could not be inserted via copying and pasting into the Database field.
If the size of a mounting surface on which several mounting aids were located was downsized from bottom to top or from left to right, the mounting aids were moved as well. When placing planning objects from the pre-planning navigator the symbol stored at the function template was not considered under specific conditions.
The Layout space: Connection filter property used the wrong decimal separators. As a result the connection filter did not function. During the placement of a part in the layout space by means of the placement options, an entered offset value was not taken into consideration immediately after the [Enter] button was pressed.
If the Potential type property was changed at a potential definition and reset to "Undefined", the potential type entered was overwritten with the "Undefined" value at the associated connection. If the contents of blocks were queried by means of the "SubPlacements" property from the "Block" class, a message resulted under specific conditions. The manufacturing data export of a layout space for Rittal-Perforex BC was not possible because of a blank in the name of the layout space.
EPLAN offers you an integrated software solution for efficient electrical engineering. Success for industrial companies is strongly related to their work in maintenance and servicing, which prevents machine and system failures and enables the best possible utilisation and availability of plant systems over their entire service life. EPLAN offers you integrated solutions for digitising your processes. To ensure cost-effective engineering processes, architects, engineers, planning offices and construction companies need a transparent foundation of information and efficient digital tools.
EPLAN solutions make it possible for you to work in an interdisciplinary way with integrated data for building automation. The term automated engineering combines configuration with engineering. In practice, this means automating engineering processes, integrating these processes and connecting them with configuration processes in sales, order processing and directly to engineering. EPLAN offers you solutions for implementing automated engineering in your company. The daily ordering business is getting much faster and time pressures are rising, no least due to international competitors.
At the same time, customers are demanding increasingly more individualised projects through to mass customisation. EPLAN is here supporting you with integrated engineering solutions along your value chain.
Consistent data is the key to success here. We support you in saving both time and costs, in avoiding errors and in increasing your productivity over the long term. Hardly any other industry is facing such enormous upheavals as the automobile industry.
With our solutions, you can optimise the entire value chain in vehicle manufacturing. EPLAN offers you solutions for engineering the control systems of machines and plant systems, supporting you in the creation, production, further processing and packaging of agricultural products into foods and beverages. Code compliance, ensuring supply, optimising load distribution: the energy sector has big challenges to face. EPLAN offers you optimal solutions for a broad field of applications from energy management to plant system engineering.
Digitalisation, standardisation and automation are all trends that no industrial sector can evade right now. This also holds true for the maritime industry. Planning monitoring, control, regulation and optimisation systems is an important part of technical facility management for all sorts of buildings. With EPLAN you can rely on a continuous and consistent database that goes far beyond just the engineering processes.
EPLAN Electric P8 is an electrical design software package which automatically generates detailed evaluations for you as an integral component of the project documentation — either on an ongoing basis or combined after project completion, as required. Downstream process steps then get all the necessary information from engineering: from integrated planning through to manufacturing, commissioning, maintenance and repair.
You can save up to 26 variants of a circuit or system for each representation type. With 12 different representation types, you have a total of possible variants at your fingertips. You can easily manage your macro projects. Thanks to macro technology, you can create a solid foundation for standardising your processes.
Manage an unlimited number of data sets for your macros and quickly select the desired data set during the engineering design process. Autoconnecting enables you to logically connect circuit symbols with one another in an instant, making schematics design faster and increasing the quality of the generated schematic.
Choose between a graphical, a logical or device-oriented design approach to support various work processes. Reports such as terminal and wire diagrams or bills of materials are automatically created for you to be used in downstream project phases.
Thanks to its end-to-end Unicode capability, the software generates circuit diagrams and schematics in a wide variety of languages based on your customised translation databases — from schematics in Chinese to bills of materials in Russian.
With our virtual walkthrough, you can experience the software for electrical engineering up close! Discover the many useful functions, highlights and features within Electric P8 click by click. If you'd like a more in-depth demonstration , our engineers will be happy to help.
The new EPLAN Platform provides the technical basis for a completely new user experience: The modern operating concept makes it easy and efficient for new users to get started with the software, and also makes daily work easier for experienced users. The optimisation of ergonomics and performance strengthen the leading position of EPLAN solutions in electrical engineering and control panel building. A Backstage view is now the central element for all project information as well as for data and file management.
The new parts management offers optimal performance and easy navigation. All of this offers added value far beyond engineering — along the integrated value chain and for the entire industrial ecosystem. Moving images explain things better! EPLAN offers you comprehensive services and support beyond our software. We are here to support you!
In addition, the consultants can work with you to unlock the enormous potential for implementing integrated working processes in your company.
Are you stuck? It shows you how to work in a functionally structured way and follow uniform standards. You can also increase your engineering efficiency step by step with a solid data basis. Find out how companies use our solutions to address current technical and business developments and improve their productivity.
The SOFIA research aircraft has now been operating for 8 years, enabling close observation of space by recording infrared radiation. The complex electrical engineering of this unique telescope has so far been available only on paper and in the form of PDF documents. The underlying principle is consistent, cross-disciplinary design processes from mechanical and process engineering through to fluid power and electrical engineering.
Good things sometimes come from chance events. Jeddah, Mecca, Benin City. Many systems are also travelling the high seas, i. This is possible only by electrical design being as consistent as possible and highly automated. Everyone is talking about Industry 4. But what about the strategic digitisation of design processes and designing control technology for machines and plant systems? Researchers at the E4TC in Aachen introduced an engineering workflow model amongst other things and prepared an evaluation matrix with five efficiency levels.